Interpolasi Newton (Sunarsih)

INTERPOLASI NEWTON UNTUK KARAKTERISTIK BIOLOGI
KUALITAS AIR LIMBAH DOMESTIK
PADA KOLAM STABILISASI FAKULTATIF INSTALASI
PENGOLAHAN AIR LIMBAH SEWON BANTUL
 
Newton Interpolation for Biology Characteristic
Wastewater Domestic Quality in Facultative Stabilization
in “IPAL Sewon Bantul” Ponds

 Sunarsih1), Purwanto2), dan Wahyu Setia Budi3)
1,2)Program Doktor Ilmu Lingkungan Universitas Diponegoro
3)Fakultas Sains dan Matematika Universitas Diponegoro
Jalan Imam Barjo, Semarang
Email: narsih_pdil@yahoo.com

 

Abstrak: Sistem pengolahan air limbah domestik di Instalasi Pengolahan Air Limbah (IPAL) Sewon Bantul termasuk konvensional, karena prosesnya mengutamakan proses alami. Proses pengolahan secara biologi untuk menurunkan BOD, COD, dan kandungan bakteri coli serta kondisi biota perairan sehingga memenuhi baku mutu lingkungan. Pengambilan sampel pada inlet dan outlet IPAL dilakukan selama satu hari dengan periode waktu 2 jam yaitu dari jam 08.00 – 16.00 dan untuk sampel pada kolam fakultatif pada jarak 0 meter, 25 meter, 50 meter dan 75 meter. Analisa data untuk mengetahui kondisi air limbah sebelum dan sesudah pengolahan dilakukan dengan uji statistik uji t. Untuk memprediksi kadar parameter pada jarak tertentu pada kolam fakultatif dihitung menggunakan interpolasi Newton. Dengan uji t menunjukkan bahwa tidak ada perbedaan di influen dan efluen kadar BOD (p>0,347) dan COD (p>0,513). Kadar total coliform setelah pengolahan menunjukkan adanya penurunan sebesar 97,1%. Dari hasil analisis data menunjukkan bahwa sebelum dan sesudah pengolahan air limbah secara statistik tidak ada perbedaan, namun secara numerik dapat menurunkan kadar BOD (72,33%) dan COD (78,67%) yang berdampak pada penurunan total coliform (97,1%) dan menjaga kondisi oksigen terlarut. Dengan demikian kadar parameter pada jarak tertentu dapat diperkirakan dengan interpolasi Newton. Kekayaan plankton tersusun atas phytoplankton dari familia Chlorophyceae, Euglenophyceae (alga) dan Bacillario-phyceae dan zooplankton dari kelompok Copepoda.

Kata kunci: proses pengolahan biologi, proses alam, Interpolasi Newton, dan limbah cair domestik.

Abstract: Domestic wastewater treatment system in WWTP Sewon Bantul is still conventional one, because the process depends on the natural processes. Biological treatment process have been used to reduce BOD, COD, and the content of coli bacteria and the condition of aquatic biota that meet environmental quality standards. Wastewater sampling are done at the inlet and outlet of WWTP for one day with in a period of 2 (two) hours, from 08:00 a.m to 16:00 p.m sampling of the facultative ponds are.distance of 0 meter, 25 meters, 50 meters and 75 meter. Data analysis is done using statistical t-tests to determine the condition of waste water before and after processing. To predict the levels of parameters at a given distance on the facultative pond, Newton interpolation is used. BOD levels (p>0.347) and COD levels (p> 0.513) are not indicated t- test was not significant, which means there is no difference between wastewater before and after distinctive treatments. The total coliform levels after treatment showed that there is of 97.1%. The analysis of data shows that before and after the processing of waste water, there is no difference, but can reduce levels of BOD (72,33%) and COD (78,67%) which affects the decrease in total coliform and maintain the dissolved oxygen (DO). By using Newton interpolation parameter levels at a certain distance can be estimated. The variety of phytoplankton are very enormous from chlorophyceae Genus, wealth is composed of phytoplankton plankton from family Chlorophyceae, Euglenophyceae (algae) and Bacillariophyceae and zooplankton from the Copepods.

Keywords: biological treatment process, Natural process, Newton Interpolation, and wastewater domestic.

Comments